LYSAGHT® FLEX-LOK™

272 จำนวนผู้เข้าชม  | 

 

LYSAGHT® FLEX-LOK™

          structural standing seam profile is the latest addition to the LYSAGHT® suite of products. Unlike our range of architectural standing seam profile, this roofing system requires no substrate as it is profiled with structural strength to function as a single skin roof to increasa its ability in thermal resistance and sound transmission. In addition, LYSAGHT® FLEX-LOK™ can be formed into straight sheet, convex curved sheet or tapered sheet to meet increasingly sophiscated roof geomertries demanded by designers today. As such, LYSAGHT® FLEX-LOK™ is the architects, engineers and contractors' ultimate choice for roofing solution.

 

          LYSAGHT® FLEX-LOK™ provides variety of material that can be used to create individual, modern building facades and imaginative roof landscapes.

 

straight

Tapered

Curve Concave

Curve Convex

Curve Convex Tapered

 

Advanteges

  • No fastener penetration ensures weather tightness performance.
  • Advance concealed clip system provide excellent uplift resistance.
  • Available on tapered and curved sheets to fulfill the most challenging design criteria.
  • Can be roll-formed on site to avoid end overlapping and to achieve. extreme length according to the project requirements.
  • Available in a range over widths in ferrous and non ferrous material.
  • Original clip design minimize the need for roofing thermal expansion joints.
  • Specially engineered thermal pad of the clip can reduce thermal bridging effects.
  • Excellent in rain drainage (high ribbed profile).
  • Thhe minimum roof pitch is 1.40.

 

 Spesification of steel

  • TCT (mm)     - 0.60/0.85
  • Coverge        - Straight 300,400*,500

                                   - Tapered 240-500

  Spesification of steel

Minimum Recommended Roof Pitch 2.5%

Minimum Radius of CurvingSmooth Pre-CurveConvex14 M
Concave18 M
Convex55 M (0.60mm)
Spring Curve60 M (0.85 mm)
Concave80 M (0.60 mm)
90 M (0.85 mm)

 

Recommended Support Spacing1.5 m - 2.0 m
Coating Mass150 g/m²
Yield Strength300 MPa
Meets Australian Standard AS 1397-2001 AS/NZS 2728-2007

*The standard width of  LYSAGHT® FLEX-LOK™ is 400 m

*The limitation data may different for various materal, please contact Bluescope Lysaght Technical Department for advice.

 

Wind Load Capacities (Kpa)

Type of SpanType of ClipSpan (mm)
900120015001800210024002700
End SpanStandard Clip3.782.851.951.461.251.171.02
Long Clip4.163.132.151.561.41.241.099
Internal SpanStandard Clip3.62.771.931.491.321.281.15
Long Clip3.963.042.131.591.431.351.23

1. Support must no be less than 1.5 mm BMT.

2. The fastened diameter of the seam is 20 mm, tolerance should be within-0.7mm-+0.3 mm.

3. Seaming up can be finished by twice fastening, first to diameter about 21-22 mm and then to the final size.

4. Values provided here are the strength of ultimate wind capacities.

 

Roofing System

          The following figures show several typical LYSAGHT® FLEX-LOK™ system commonly encountered. Obviously, thhe system are dependent on specific and should be tailored to suit the thermal, acoustic, ventilation or economic requirement.

 

Double Skin Rafter/Truss Roof System-Clip fixed to W-DEK® rib

 

Double Skin Rafter/Truss Roof System-Clip fixed to W-DEK® rib

1. LYSAGHT® FLEX-LOK™ Panel

2. Gypsum Board (Optional)

3. Insulation

4. FLEX-LOK™ Clip

5. Galvanized 2W/3W-DEK®

6. The Main Beam of Roof

 

Double Skin Rafter/Truss Roof System-Clip fixed to sub-purlin

 

Double Skin Rafter/Truss Roof System-Clip fixed to sub-purlin

1. LYSAGHT® FLEX-LOK™ Panel

2. FLEX-LOK™ Clip

3. Insulation

4. Vapour Barrier : Alumunium Foil

5. Acoustextile

6. Nonwaven Fabric

7. Galvanized Z Sub Purlin

8. The Main Beam of Roof

9. Galvanized 2W/3W-DEK® (Perforation 23%)

 

Double Skin Purlin Rooof System-Clip fixed to sub-purlin

 

Double Skin Purlin Rooof System-Clip fixed to sub-purlin

1. LYSAGHT® FLEX-LOK™ Panel

2. Insulation

3. FLEX-LOK™ Clip

4. Vapour Barrier : Alumunium Foil

5. The Sub Purlin of Roof

6. The Main Purlin of Roof

7. TRIMDEK® Celling (Perforation 23%)

 

Single Skin Purlin Roof System

 

Single Skin Purlin Roof System

1. LYSAGHT® FLEX-LOK™ Panel

2. Insulation

3. Vapour Barrier

4. FLEX-LOK™ Clip

5. The Main Purlin of Roof

 

Fixing Clips

Fixing Clips

 

Step 1 : 

          Fixing clips, FLEX-LOK™ is anchored onto the purliins with heat insulated concealed clips. Pay attention to the correct direction.

Step 2 :

          Fixing male and female ribs on the clips. Place the fermale rib overlapping on the male rib from the previous sheet.

Step 3 :

          Lock up (seam) the ribs using machine on site.

 

Installation Process

Double Skin typical use for Roofing/Walling Linier

 

Fixing inner sheet profile substrate on the purlin with self-drilling screw.

Step 1 :

          Fixing inner sheet profile substrate on the purlin with self-drilling screw.

 

Fixing Z-subgirt on the substrate with sself-drilling screw.

Step 2 :

          Fixing Z-subgirt on the substrate with sself-drilling screw.

 

 Fixing clips on the Z-subgirt with self-drilling screw.

Step 3 : 

          Fixing clips on the Z-subgirt with self-drilling screw.

 

Laying insulation on the substrate and  pressing for clip exposure.

Step 4 :

          Laying insulation on the substrate and  pressing for clip exposure.

 

Laying LYSAGHT® FLEX-LOK™ sheet on the clip with hand seamer on the end of rib.

Step 5 :

          Laying LYSAGHT® FLEX-LOK™ sheet on the clip with hand seamer on the end of rib.

 

Clamping the seamer on the end of rib and seaming aling the length of roof.

Step 6 :

          Clamping the seamer on the end of rib and seaming aling the length of roof.

 

Tools & Accessories

Mechanical Seamer

Mechanical Seamer

Mechanical Seamer

Mechanical Seamer

          LYSAGHT® FLEX-LOK™'s system seamed onto the clips using aa mechanical seaning process. The seamer consists of two seaming rolles that are clamped onto FLEX-LOK™ panel, plus four guides to ensure the correct height is maintained.

 

Hand Seamer

Hand Seamer

         The first 200-300 mm should be hand crimped to enable the seamer to be clamped onto the sheet. The hand tool is used by squeezing the handles inward to close the seam.

 

FLEX-LOK™ Clips

FLEX-LOK™ Clips

          FLEX-LOK™ Clips are extruded from structural grade aluminum. The shape of the clip has been carefully designed to minimize the strength, in both upward (wind uplift) and downward (wind, dead load) conditions. The head of the clips accurately matches the FLEX-LOK™ sheeting to ensure the sheets slide freely during thermal movement.

 

Thermal Pad

Thermal Pad

          Specially engineered thered pad slides neatly onto base of the clip which can reduce or eliminate thermal bridging effects.

 

Project Referenced

Project Referenced

Project Referenced Project Referenced

 

บทความที่เกี่ยวข้อง

1. แผ่นหลังคาและผนังเหล็ก LYSAGHT TRIMDEK®

2. หลังคา LYSAGHT® KLIP-LOK® OPTIMA™ 

3. แผ่นหลังคาและผนังเหล็ก LYSAGHT KLIP-LOK® 700 

4. หลังคาและผนังความแข็งแรงสูง LYSAGHT KLIP-LOK 700 HI-STRENGTH®

5. แผ่นหลังคาและผนังเหล็ก LYSAGHT HR-29™ HITENSILE

6. แผ่นผนังเหล็ก LYSAGHT PANELRIB® HI-TEN

7. หลังคา LYSAGHT® ZIPDEK®

8. หลังคา LYSAGHT® LOCKED SEAM®

9. ผลิตภัณฑ์ เมทัลชีท WONGGURU

 

 

 

Powered by MakeWebEasy.com
เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว  และ  นโยบายคุกกี้